{"schema_version":"1.0","package_type":"agent_readable_article","generated_at":"2026-06-06T17:31:45+00:00","article":{"id":13483,"slug":"how-to-specify-valves-for-atex-hazloc-environments","title":"Kā noteikt vārstus ATEX / HazLoc videi","url":"https://rodlesspneumatic.com/lv/blog/how-to-specify-valves-for-atex-hazloc-environments/","language":"lv","published_at":"2025-11-17T01:04:59+00:00","modified_at":"2025-11-17T01:05:01+00:00","author":{"id":1,"name":"Bepto"},"summary":"Lai noteiktu vārstus ATEX/HazLoc videi, jāizvēlas sprādziendroši pneimatiskie komponenti, kas sertificēti saskaņā ar EN 13463 (ATEX) vai NEC 500/505 (HazLoc) standartiem, nodrošinot, ka atbilstošā temperatūras klase, zonas kategorija un aizdegšanās aizsardzības metodes atbilst jūsu konkrētajai bīstamās zonas klasifikācijai.","word_count":2736,"taxonomies":{"categories":[{"id":97,"name":"Pneimatiskie cilindri","slug":"pneumatic-cylinders","url":"https://rodlesspneumatic.com/lv/blog/category/pneumatic-cylinders/"}],"tags":[{"id":156,"name":"Pamatprincipi","slug":"basic-principles","url":"https://rodlesspneumatic.com/lv/blog/tag/basic-principles/"}]},"sections":[{"heading":"Ievads","level":0,"content":"![ATEX](https://rodlesspneumatic.com/wp-content/uploads/2025/09/ATEX.png)\n\nATEX\n\nJa jūsu ražošanas līnija darbojas sprādzienbīstamā vidē, viena nepareiza vārsta izvēle var izraisīt katastrofālas kļūmes, sodanaudas vai, vēl ļaunāk, traumas darba vietā. Likme ir neticami augsta, un kļūdas iespēja ir nulle. Tomēr daudzi inženieri joprojām cīnās ar sarežģītību. [ATEX](https://single-market-economy.ec.europa.eu/sectors/mechanical-engineering/equipment-potentially-explosive-atmospheres-atex_en)[1](#fn-1) un [HazLoc](https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.307)[2](#fn-2) atbilstības standartiem.\n\n**Lai noteiktu vārstus ATEX/HazLoc videi, jāizvēlas sprādziendroši pneimatiskie komponenti, kas sertificēti saskaņā ar EN 13463 (ATEX) vai NEC 500/505 (HazLoc) standartiem, nodrošinot, ka atbilstošā temperatūras klase, zonas kategorija un aizdegšanās aizsardzības metodes atbilst jūsu konkrētajai bīstamās zonas klasifikācijai.** Tas ietver materiālu saderības pārbaudi, elektriskā zemējuma prasības un atbilstošas dokumentācijas iegūšanu no sertificētiem piegādātājiem.\n\nNesen runāju ar Deividu, tehniskās apkopes inženieri no ķīmiskās pārstrādes rūpnīcas Luiziānā, kurš saskārās ar divu nedēļu dīkstāvi, jo viņa iepirkumu komanda pasūtīja standarta solenoīdu vārstus, nevis HazLoc sertificētas vienības. Regulatīvā inspekcija to konstatēja pirms palaišanas - tas glāba cilvēku dzīvības, bet uzņēmumam izmaksāja vairāk nekā $400 000 ražošanas kavējumu. Ļaujiet man palīdzēt jums izvairīties no līdzīgām dārgām kļūdām."},{"heading":"Saturs","level":2,"content":"- [Kas ir ATEX un HazLoc klasifikācija un kāpēc tās ir svarīgas?](#what-are-atex-and-hazloc-classifications-and-why-do-they-matter)\n- [Kā noteikt pareizo vārstu sertifikāciju jūsu lietojumam?](#how-do-you-determine-the-right-valve-certification-for-your-application)\n- [Kādām tehniskajām specifikācijām jāatbilst ATEX/HazLoc vārstiem?](#what-technical-specifications-must-atexhazloc-valves-meet)\n- [Kā Bepto var palīdzēt jums rentabli atrast atbilstošus vārstus?](#how-can-bepto-help-you-source-compliant-vales-cost-effectively)"},{"heading":"Kas ir ATEX un HazLoc klasifikācija un kāpēc tās ir svarīgas?","level":2,"content":"Izpratne par sprādziendrošības standartiem nav saistīta tikai ar atbilstību - tā ir saistīta ar dzīvības un aktīvu aizsardzību vidē, kur uzliesmojošas gāzes, tvaiki vai putekļi rada aizdegšanās risku. ⚠️\n\n**ATEX (ATmosphères EXplosibles) ir Eiropas direktīva, kas reglamentē sprādzienbīstamā vidē izmantojamās iekārtas, savukārt HazLoc (Hazardous Location) attiecas uz Ziemeļamerikas standartiem saskaņā ar NEC un CEC kodeksiem.** Abas sistēmas klasificē bīstamās zonas pa zonām/daļām, un, lai novērstu sprādzienus, ir nepieciešams sertificēts aprīkojums ar atbilstošām aizdegšanās aizsardzības metodēm.\n\n![HazLoc](https://rodlesspneumatic.com/wp-content/uploads/2025/11/HazLoc.png)\n\nHazLoc"},{"heading":"Divas galvenās standartu sistēmas","level":3,"content":"**ATEX (Eiropas Savienība):**\n\n- Pārvalda [Direktīva 2014/34/ES](https://eur-lex.europa.eu/eli/dir/2014/34/oj/eng)[3](#fn-3)\n- Izmantošana Zonu klasifikācija (0., 1., 2. zona gāzēm; 20., 21., 22. zona putekļiem)\n- Nepieciešams CE marķējums un paziņotās struktūras sertifikācija\n- Aprīkojuma kategorijas: 1G, 2G, 3G (gāze) un 1D, 2D, 3D (putekļi).\n\n**HazLoc (Ziemeļamerika):**\n\n- Ievēro NEC 500. pantu (klase/dalījums) vai 505. pantu (zonu sistēma).\n- I klase (gāzes/ tvaiki), II klase (degoši putekļi), III klase (šķiedras).\n- 1. un 2. nodalījums norāda bīstamības klātbūtnes varbūtību.\n- Nepieciešama UL, CSA vai FM sertifikācija."},{"heading":"Kāpēc tas ir svarīgi vārstu izvēlei","level":3,"content":"Kad mēs piegādājam pneimatiskos vārstus un bezstieņa cilindrus iekārtām bīstamās zonās, sertifikācija nav obligāta - tā ir juridiski obligāta. Nesen ar mūsu komandu sazinājās kāds farmācijas ražošanas uzņēmums Ņūdžersijā pēc tam, kad oriģināliekārtu ražotāju piegādātājs viņiem piedāvāja $8 500 par vienu ATEX sertificētu vārsta komplektu ar 8 nedēļu izpildes termiņu. Mēs piedāvājām līdzvērtīgu Bepto sertificētu risinājumu par 40% mazāku cenu, kas tika piegādāts 12 dienu laikā.\n\nGalvenā atšķirība? Mēs uzturam stratēģisku sertificētu komponentu krājumu un izprotam ATEX un HazLoc standartu savstarpējās sertifikācijas ekvivalenci."},{"heading":"Kā noteikt pareizo vārstu sertifikāciju jūsu lietojumam?","level":2,"content":"Lai izvēlētos pareizo sertifikāciju, ir nepieciešama sistemātiska pieeja zonas klasifikācijai un riska novērtēšanai - sprādzienbīstamā vidē nav pieļaujams veikt minējumus.\n\n**Vispirms ir jāsaņem objekta bīstamo zonu klasifikācijas rasējumi, jānosaka konkrētā zona/nodalījums un gāzes grupa jūsu uzstādīšanas vietai, pēc tam jāsaskaņo vārstu sertifikācija ar šiem precīzajiem parametriem, tostarp temperatūras klasi (T1-T6) un gāzes grupu. [iekārtas aizsardzības līmenis (EPL)](https://www.iecex.com/resources-and-news/standards/)[4](#fn-4).** Šis uz dokumentāciju balstītais process nodrošina atbilstību normatīvajiem aktiem un darbības drošību.\n\n![2S sērijas nerūsējošā tērauda 22 virzienu solenoīda vārsts (normāli slēgts)](https://rodlesspneumatic.com/wp-content/uploads/2025/05/2S-Series-Stainless-Steel-22-Way-Solenoid-Valve-Normally-Closed-1.jpg)\n\n[Normāli atvērtie elektromagnētiskie vārsti - misiņa (2W) un nerūsējošā tērauda (2S) sērija](https://rodlesspneumatic.com/lv/products/control-components/normally-open-solenoid-valves-brass-2w-stainless-steel-2s-series/)"},{"heading":"Soli pa solim sertifikācijas saskaņošanas process","level":3},{"heading":"1. Nosakiet savas teritorijas klasifikāciju","level":4,"content":"- Objekta P\u0026ID un platību klasifikācijas rasējumu pārskatīšana\n- Noteikt zonu (ATEX) vai nodaļu (HazLoc)\n- Noteikt gāzes grupu (IIA, IIB, IIC) vai putekļu īpašības\n- Piezīme Temperatūras klases prasības"},{"heading":"2. Atbilstošas vārstu aizsardzības metodes","level":4,"content":"Biežāk sastopamie aizdegšanās aizsardzības veidi ir šādi:\n\n- **Ex d (ugunsdrošs)**: Sprādziena ierobežošana\n- **Ex e (paaugstināta drošība)**: Dzirksteļu/karstu virsmu novēršana\n- **Ex ia/ib ([Īpatnējā drošība](https://www.prelectronics.com/what-is-intrinsic-safety/)[5](#fn-5))**: Enerģijas ierobežojums\n- **Ex nA (bez dzirksteles)**: Piemērots 2. zonas/2. nodaļas lietojumiem"},{"heading":"3. Temperatūras klases verifikācija","level":4,"content":"Vārsta maksimālajai virsmas temperatūrai jābūt zemākai par bīstamās vielas aizdegšanās temperatūru:\n\n| Temperatūras klase | Maksimālā virsmas temperatūra | Vielu piemēri |\n| T1 | 450°C | Acetons, amonjaks |\n| T2 | 300°C | Etanols, benzīns |\n| T3 | 200°C | Dīzeļdegviela |\n| T4 | 135°C | Acetaldehīds |\n| T5 | 100°C | Oglekļa disulfīds |\n| T6 | 85°C | Dažas speciālās ķimikālijas |"},{"heading":"Reāla lietojuma piemērs","level":3,"content":"Sārai, projektu inženierei naftas pārstrādes rūpnīcā Teksasā, vajadzēja nomainīt novecojušos solenoīdu vārstus 1. zonas zonā, kurā ir ūdeņraža gāze (IIC grupa, T1). Viņas sākotnējais oriģinālais oriģināliekārtu ražotājs piedāvāja vārstus, kas sertificēti tikai IIB grupai - nepietiekami ūdeņraža lietojumiem. Mēs viņai piegādājām pareizi novērtētus Ex d IIC T4 sertificētus vārstu kolektorus, kas atbilda visām NEC 505 prasībām, novēršot potenciāli bīstamu specifikācijas kļūdu. ✅"},{"heading":"Kādām tehniskajām specifikācijām jāatbilst ATEX/HazLoc vārstiem?","level":2,"content":"Sprādziendrošajiem vārstiem ir jāatbilst ne tikai pamata sertifikācijas marķējumam, bet arī stingrām tehniskajām prasībām, kas ietekmē gan drošību, gan ilgtermiņa uzticamību skarbos vides apstākļos.\n\n**ATEX/HazLoc vārstiem nepieciešama specializēta konstrukcija, tostarp sprādziendrošs korpuss, atbilstošs IP novērtējums (parasti IP65 vai augstāks), sertificēti kabeļu vadi, ekvipotenciālā savienojuma noteikumi un materiāli, kas izturīgi pret korozīvu atmosfēru, vienlaikus saglabājot virsmas temperatūras ierobežojumus visos darba apstākļos.** Dokumentācijā jāiekļauj uzstādīšanas instrukcijas, tehniskās apkopes procedūras un atbilstības sertifikāts."},{"heading":"Kritiskās tehniskās prasības","level":3},{"heading":"Elektriskie komponenti","level":4,"content":"- Elektromagnētiskajām spolēm jābūt sertificētām konkrētai zonai/daļai.\n- Spriegumam un frekvencei jāatbilst sertifikācijas parametriem\n- Ievadiem cauruļvados ir nepieciešami sertificēti kabeļu ieliktņi.\n- Obligātie zemējuma/savienojuma noteikumi"},{"heading":"Mehāniskā būvniecība","level":4,"content":"- Apvalka materiāli: Parasti alumīnijs vai nerūsējošais tērauds\n- Aizsardzība pret iekļūšanu: Minimālais IP65 āra/mazgāšanas telpām\n- Izturība pret koroziju: Apsveriet jūras klases vai īpašus pārklājumus.\n- Izturība pret vibrācijām: Saskaņā ar IEC 60068-2-6 standartiem"},{"heading":"Veiktspējas salīdzinājums: Bepto vs. OEM","level":4,"content":"| Funkcija | OEM sertificēti vārsti | Bepto sertificēti vārsti |\n| ATEX/HazLoc sertifikācija | ✅ Jā | ✅ Jā (ekvivalents) |\n| Izpildes laiks | 6-10 nedēļas | 1-2 nedēļas |\n| Cenu punkts | Pamatlīnija | 30-40% apakšējā |\n| Tehniskais atbalsts | Ierobežots | Tieša piekļuve inženierim |\n| Pielāgošanas opcijas | Ierobežots | Elastīgas konfigurācijas |\n| Rezerves daļu pieejamība | Bieži kavējas | Stratēģisko krājumu saglabāšana |"},{"heading":"Dokumentācijas prasības","level":3,"content":"Pasūtot pie mums sertificētus vārstus, mēs nodrošinām:\n\n- Atbilstības sertifikāts (CoC)\n- ES atbilstības deklarācija (ATEX)\n- Uzstādīšanas un apkopes rokasgrāmatas angļu valodā\n- Rezerves daļu saraksti ar sertifikācijas informāciju\n- Izsekojamības dokumentācija kvalitātes auditiem\n\nMūsu dokumentācijas pakete ir palīdzējusi klientiem izturēt regulatīvo auditu vairāk nekā 30 valstīs, sākot no farmācijas rūpnīcām Šveicē līdz naftas ķīmijas rūpnīcām Saūda Arābijā."},{"heading":"Kā Bepto var palīdzēt jums rentabli atrast atbilstošus vārstus?","level":2,"content":"Lai orientētos sarežģītajā sprādziendrošās pneimatikas pasaulē, nav jāizsmeļ jūsu budžets vai jāpagarina projekta termiņi - ja sadarbojaties ar pareizo partneri.\n\n**Bepto specializējas ATEX un HazLoc sertificētu pneimatisko vārstu, cilindru bez stieņiem un pilnu pneimatisko sistēmu nodrošināšanā kā rentablu alternatīvu oriģināliekārtu ražotāju komponentiem ar līdzvērtīgiem sertifikātiem, ātrāku piegādi un pieredzējušu inženieru, kas pārzina gan Eiropas, gan Ziemeļamerikas standartus, tehnisko atbalstu.** Mēs uzturam stratēģisku sertificētu komponentu krājumu, lai samazinātu dīkstāves risku."},{"heading":"Mūsu sertifikācijas portfelis","level":3,"content":"Mēs aktīvi sertificējamies dažādos standartos:\n\n- **ATEX**: 2G/2D kategorija (zona 1/21) un 3G/3D (zona 2/22)\n- **IECEx**: Starptautiska sertifikācija globāliem projektiem\n- **UL/CSA**: Ziemeļamerikas HazLoc atbilstība\n- **KOSHA**: Korejas sertifikācija Āzijas tirgiem"},{"heading":"Bepto priekšrocības lietojumiem bīstamās zonās","level":3},{"heading":"Ātrāka piegāde","level":4,"content":"Lai gan oriģināliekārtu ražotāju piegādātājiem sertificētas sastāvdaļas bieži vien ir nepieciešamas 8-12 nedēļas, mūsu stratēģiskie krājumi ļauj mums piegādāt lielāko daļu standarta konfigurāciju 5-10 darba dienu laikā. Pielāgotas konfigurācijas mēs parasti piegādājam 3-4 nedēļu laikā - joprojām 50% ātrāk nekā tradicionālie piegādātāji."},{"heading":"Izmaksu optimizācija bez kompromisiem","level":4,"content":"Mūsu uzņēmējdarbības modelis ir vērsts uz sertificētu rezerves komponentu, kas atbilst vai pārsniedz oriģināliekārtu ražotāju specifikācijas, nodrošināšanu par ievērojami zemākām cenām. Nesen kāds pārtikas pārstrādes uzņēmums Ontārio provincē nomainīja visu pneimatiskās vadības sistēmu ar Bepto sertificētiem vārstiem, ietaupot $47 000 projekta laikā, vienlaikus nodrošinot pilnīgu atbilstību Kanādas HazLoc prasībām."},{"heading":"Tehniskās konsultācijas","level":4,"content":"Sazinoties ar mums, jūs runāsiet tieši ar inženieriem, kuri saprot:\n\n- Teritoriju klasifikācijas metodoloģijas\n- Savstarpējās sertifikācijas ekvivalenti (ATEX ↔ HazLoc)\n- Materiālu izvēle korozīvām vidēm\n- Integrācija ar esošajām vadības sistēmām\n- Tehniskās apkopes optimizācijas stratēģijas"},{"heading":"Darba sākšana","level":3,"content":"Ja plānojat projektu bīstamā zonā vai ja nepieciešams nomainīt esošos sertificētos komponentus, sazinieties ar mūsu komandu. Mēs izskatīsim jūsu specifikācijas, apstiprināsim sertifikācijas prasības un sniegsim detalizētu piedāvājumu ar sertifikācijas dokumentāciju - parasti 24 stundu laikā."},{"heading":"Secinājums","level":2,"content":"Lai noteiktu vārstus ATEX un HazLoc videi, ir jāpievērš īpaša uzmanība sertifikācijas standartiem, tehniskajām specifikācijām un atbilstošai dokumentācijai, taču ar pareizo piegādātāju partneri jūs varat panākt pilnīgu atbilstību, vienlaikus ievērojami samazinot izmaksas un sagatavošanas laiku."},{"heading":"Bieži uzdotie jautājumi par ATEX HazLoc vārstu specifikāciju","level":2},{"heading":"**J: Vai Ziemeļamerikas HazLoc lietojumos var izmantot ATEX sertificētus vārstus?**","level":3,"content":"ATEX un HazLoc sertifikāti nav tieši savstarpēji aizvietojami, lai gan iekārtām var būt divi sertifikāti. Jums jāpārliecinās, vai jūsu vārstam ir konkrētais sertifikāts, ko pieprasa jūsu vietējā jurisdikcija - ATEX - ES, UL/CSA - Ziemeļamerikā. Mēs varam piegādāt vārstus ar dubultu sertifikāciju, lai vienkāršotu globālos projektus."},{"heading":"**J: Kāda ir atšķirība starp 1. un 2. zonas vārstu prasībām?**","level":3,"content":"1. zonas (vai 1. nodaļas) zonās pastāvīgi vai bieži ir sprādzienbīstama vide, tāpēc ir nepieciešami augstāki aizsardzības līmeņi, piemēram, Ex d vai Ex ia. 2. zonas (2. nodaļas) zonās bīstamība pastāv tikai ārkārtējos apstākļos, un tajās pieļaujamas vienkāršākas aizsardzības metodes, piemēram, Ex nA. 1. zonas iekārtas var izmantot 2. zonā, bet ne otrādi."},{"heading":"**J: Cik bieži jāpārsertificē vai jāpārbauda ATEX/HazLoc vārsti?**","level":3,"content":"Pašiem vārstiem nav nepieciešama atkārtota sertifikācija, taču jūsu objektā ir jāveic regulāras pārbaudes saskaņā ar vietējiem noteikumiem - parasti reizi gadā 1. zonas 1. nodaļas zonās. Veiciet uzstādīšanas uzskaiti, vizuāli pārbaudiet, vai nav bojājumu, un pārliecinieties par pareizu zemējumu. Katram pasūtījumam mēs pievienojam tehniskās apkopes vadlīnijas, lai palīdzētu jums nodrošināt atbilstību prasībām."},{"heading":"**J: Vai pneimatiskie vārsti sprādzienbīstamā vidē ir drošāki par elektriskajiem vārstiem?**","level":3,"content":"Pneimatiskie vārsti parasti rada mazāku aizdegšanās risku, jo to iedarbināšanas punktā nav elektrisko komponentu, lai gan solenoīda pilotvārstiem joprojām nepieciešama atbilstoša sertifikācija. Pneimatiskās sistēmas var būt izdevīgas īpaši bīstamās zonās. Mēs varam jums palīdzēt novērtēt labāko pieeju jūsu konkrētajam lietojumam un riska profilam."},{"heading":"**J: Kas notiek, ja es bīstamā zonā uzstādu nesertificētus vārstus?**","level":3,"content":"Nesertificēta aprīkojuma uzstādīšana klasificētās zonās pārkāpj drošības noteikumus, anulē apdrošināšanas segumu, jūsu uzņēmumam draud lielas soda naudas un, kas ir vissvarīgākais, rada patiesu sprādziena risku, kas apdraud personālu. Pārvaldes inspektori pieprasīs nekavējoties pārtraukt darbu, līdz tiks uzstādītas atbilstošas iekārtas. Pirms uzstādīšanas vienmēr pārbaudiet sertifikāciju - mūsu komanda var palīdzēt ātri apstiprināt atbilstību.\n\n1. Izlasiet Eiropas Komisijas oficiālās vadlīnijas par ATEX. [↩](#fnref-1_ref)\n2. Skatiet OSHA un NEC bīstamo vietu (HazLoc) definīcijas. [↩](#fnref-2_ref)\n3. Piekļūstiet ES Direktīvas 2014/34/ES pilnam juridiskajam tekstam. [↩](#fnref-3_ref)\n4. Uzziniet vairāk par IEC 60079-0 standartu attiecībā uz iekārtu aizsardzības līmeņiem (EPL). [↩](#fnref-4_ref)\n5. Izpratne par iekšējās drošības (IS) principiem kā aizsardzības pret aizdegšanos metodi. [↩](#fnref-5_ref)"}],"source_links":[{"url":"https://single-market-economy.ec.europa.eu/sectors/mechanical-engineering/equipment-potentially-explosive-atmospheres-atex_en","text":"ATEX","host":"single-market-economy.ec.europa.eu","is_internal":false},{"url":"#fn-1","text":"1","is_internal":false},{"url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.307","text":"HazLoc","host":"www.osha.gov","is_internal":false},{"url":"#fn-2","text":"2","is_internal":false},{"url":"#what-are-atex-and-hazloc-classifications-and-why-do-they-matter","text":"Kas ir ATEX un HazLoc klasifikācija un kāpēc tās ir svarīgas?","is_internal":false},{"url":"#how-do-you-determine-the-right-valve-certification-for-your-application","text":"Kā noteikt pareizo vārstu sertifikāciju jūsu lietojumam?","is_internal":false},{"url":"#what-technical-specifications-must-atexhazloc-valves-meet","text":"Kādām tehniskajām specifikācijām jāatbilst ATEX/HazLoc vārstiem?","is_internal":false},{"url":"#how-can-bepto-help-you-source-compliant-vales-cost-effectively","text":"Kā Bepto var palīdzēt jums rentabli atrast atbilstošus vārstus?","is_internal":false},{"url":"https://eur-lex.europa.eu/eli/dir/2014/34/oj/eng","text":"Direktīva 2014/34/ES","host":"eur-lex.europa.eu","is_internal":false},{"url":"#fn-3","text":"3","is_internal":false},{"url":"https://www.iecex.com/resources-and-news/standards/","text":"iekārtas aizsardzības līmenis (EPL)","host":"www.iecex.com","is_internal":false},{"url":"#fn-4","text":"4","is_internal":false},{"url":"https://rodlesspneumatic.com/lv/products/control-components/normally-open-solenoid-valves-brass-2w-stainless-steel-2s-series/","text":"Normāli atvērtie elektromagnētiskie vārsti - misiņa (2W) un nerūsējošā tērauda (2S) sērija","host":"rodlesspneumatic.com","is_internal":true},{"url":"https://www.prelectronics.com/what-is-intrinsic-safety/","text":"Īpatnējā drošība","host":"www.prelectronics.com","is_internal":false},{"url":"#fn-5","text":"5","is_internal":false},{"url":"#fnref-1_ref","text":"↩","is_internal":false},{"url":"#fnref-2_ref","text":"↩","is_internal":false},{"url":"#fnref-3_ref","text":"↩","is_internal":false},{"url":"#fnref-4_ref","text":"↩","is_internal":false},{"url":"#fnref-5_ref","text":"↩","is_internal":false}],"content_markdown":"![ATEX](https://rodlesspneumatic.com/wp-content/uploads/2025/09/ATEX.png)\n\nATEX\n\nJa jūsu ražošanas līnija darbojas sprādzienbīstamā vidē, viena nepareiza vārsta izvēle var izraisīt katastrofālas kļūmes, sodanaudas vai, vēl ļaunāk, traumas darba vietā. Likme ir neticami augsta, un kļūdas iespēja ir nulle. Tomēr daudzi inženieri joprojām cīnās ar sarežģītību. [ATEX](https://single-market-economy.ec.europa.eu/sectors/mechanical-engineering/equipment-potentially-explosive-atmospheres-atex_en)[1](#fn-1) un [HazLoc](https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.307)[2](#fn-2) atbilstības standartiem.\n\n**Lai noteiktu vārstus ATEX/HazLoc videi, jāizvēlas sprādziendroši pneimatiskie komponenti, kas sertificēti saskaņā ar EN 13463 (ATEX) vai NEC 500/505 (HazLoc) standartiem, nodrošinot, ka atbilstošā temperatūras klase, zonas kategorija un aizdegšanās aizsardzības metodes atbilst jūsu konkrētajai bīstamās zonas klasifikācijai.** Tas ietver materiālu saderības pārbaudi, elektriskā zemējuma prasības un atbilstošas dokumentācijas iegūšanu no sertificētiem piegādātājiem.\n\nNesen runāju ar Deividu, tehniskās apkopes inženieri no ķīmiskās pārstrādes rūpnīcas Luiziānā, kurš saskārās ar divu nedēļu dīkstāvi, jo viņa iepirkumu komanda pasūtīja standarta solenoīdu vārstus, nevis HazLoc sertificētas vienības. Regulatīvā inspekcija to konstatēja pirms palaišanas - tas glāba cilvēku dzīvības, bet uzņēmumam izmaksāja vairāk nekā $400 000 ražošanas kavējumu. Ļaujiet man palīdzēt jums izvairīties no līdzīgām dārgām kļūdām.\n\n## Saturs\n\n- [Kas ir ATEX un HazLoc klasifikācija un kāpēc tās ir svarīgas?](#what-are-atex-and-hazloc-classifications-and-why-do-they-matter)\n- [Kā noteikt pareizo vārstu sertifikāciju jūsu lietojumam?](#how-do-you-determine-the-right-valve-certification-for-your-application)\n- [Kādām tehniskajām specifikācijām jāatbilst ATEX/HazLoc vārstiem?](#what-technical-specifications-must-atexhazloc-valves-meet)\n- [Kā Bepto var palīdzēt jums rentabli atrast atbilstošus vārstus?](#how-can-bepto-help-you-source-compliant-vales-cost-effectively)\n\n## Kas ir ATEX un HazLoc klasifikācija un kāpēc tās ir svarīgas?\n\nIzpratne par sprādziendrošības standartiem nav saistīta tikai ar atbilstību - tā ir saistīta ar dzīvības un aktīvu aizsardzību vidē, kur uzliesmojošas gāzes, tvaiki vai putekļi rada aizdegšanās risku. ⚠️\n\n**ATEX (ATmosphères EXplosibles) ir Eiropas direktīva, kas reglamentē sprādzienbīstamā vidē izmantojamās iekārtas, savukārt HazLoc (Hazardous Location) attiecas uz Ziemeļamerikas standartiem saskaņā ar NEC un CEC kodeksiem.** Abas sistēmas klasificē bīstamās zonas pa zonām/daļām, un, lai novērstu sprādzienus, ir nepieciešams sertificēts aprīkojums ar atbilstošām aizdegšanās aizsardzības metodēm.\n\n![HazLoc](https://rodlesspneumatic.com/wp-content/uploads/2025/11/HazLoc.png)\n\nHazLoc\n\n### Divas galvenās standartu sistēmas\n\n**ATEX (Eiropas Savienība):**\n\n- Pārvalda [Direktīva 2014/34/ES](https://eur-lex.europa.eu/eli/dir/2014/34/oj/eng)[3](#fn-3)\n- Izmantošana Zonu klasifikācija (0., 1., 2. zona gāzēm; 20., 21., 22. zona putekļiem)\n- Nepieciešams CE marķējums un paziņotās struktūras sertifikācija\n- Aprīkojuma kategorijas: 1G, 2G, 3G (gāze) un 1D, 2D, 3D (putekļi).\n\n**HazLoc (Ziemeļamerika):**\n\n- Ievēro NEC 500. pantu (klase/dalījums) vai 505. pantu (zonu sistēma).\n- I klase (gāzes/ tvaiki), II klase (degoši putekļi), III klase (šķiedras).\n- 1. un 2. nodalījums norāda bīstamības klātbūtnes varbūtību.\n- Nepieciešama UL, CSA vai FM sertifikācija.\n\n### Kāpēc tas ir svarīgi vārstu izvēlei\n\nKad mēs piegādājam pneimatiskos vārstus un bezstieņa cilindrus iekārtām bīstamās zonās, sertifikācija nav obligāta - tā ir juridiski obligāta. Nesen ar mūsu komandu sazinājās kāds farmācijas ražošanas uzņēmums Ņūdžersijā pēc tam, kad oriģināliekārtu ražotāju piegādātājs viņiem piedāvāja $8 500 par vienu ATEX sertificētu vārsta komplektu ar 8 nedēļu izpildes termiņu. Mēs piedāvājām līdzvērtīgu Bepto sertificētu risinājumu par 40% mazāku cenu, kas tika piegādāts 12 dienu laikā.\n\nGalvenā atšķirība? Mēs uzturam stratēģisku sertificētu komponentu krājumu un izprotam ATEX un HazLoc standartu savstarpējās sertifikācijas ekvivalenci.\n\n## Kā noteikt pareizo vārstu sertifikāciju jūsu lietojumam?\n\nLai izvēlētos pareizo sertifikāciju, ir nepieciešama sistemātiska pieeja zonas klasifikācijai un riska novērtēšanai - sprādzienbīstamā vidē nav pieļaujams veikt minējumus.\n\n**Vispirms ir jāsaņem objekta bīstamo zonu klasifikācijas rasējumi, jānosaka konkrētā zona/nodalījums un gāzes grupa jūsu uzstādīšanas vietai, pēc tam jāsaskaņo vārstu sertifikācija ar šiem precīzajiem parametriem, tostarp temperatūras klasi (T1-T6) un gāzes grupu. [iekārtas aizsardzības līmenis (EPL)](https://www.iecex.com/resources-and-news/standards/)[4](#fn-4).** Šis uz dokumentāciju balstītais process nodrošina atbilstību normatīvajiem aktiem un darbības drošību.\n\n![2S sērijas nerūsējošā tērauda 22 virzienu solenoīda vārsts (normāli slēgts)](https://rodlesspneumatic.com/wp-content/uploads/2025/05/2S-Series-Stainless-Steel-22-Way-Solenoid-Valve-Normally-Closed-1.jpg)\n\n[Normāli atvērtie elektromagnētiskie vārsti - misiņa (2W) un nerūsējošā tērauda (2S) sērija](https://rodlesspneumatic.com/lv/products/control-components/normally-open-solenoid-valves-brass-2w-stainless-steel-2s-series/)\n\n### Soli pa solim sertifikācijas saskaņošanas process\n\n#### 1. Nosakiet savas teritorijas klasifikāciju\n\n- Objekta P\u0026ID un platību klasifikācijas rasējumu pārskatīšana\n- Noteikt zonu (ATEX) vai nodaļu (HazLoc)\n- Noteikt gāzes grupu (IIA, IIB, IIC) vai putekļu īpašības\n- Piezīme Temperatūras klases prasības\n\n#### 2. Atbilstošas vārstu aizsardzības metodes\n\nBiežāk sastopamie aizdegšanās aizsardzības veidi ir šādi:\n\n- **Ex d (ugunsdrošs)**: Sprādziena ierobežošana\n- **Ex e (paaugstināta drošība)**: Dzirksteļu/karstu virsmu novēršana\n- **Ex ia/ib ([Īpatnējā drošība](https://www.prelectronics.com/what-is-intrinsic-safety/)[5](#fn-5))**: Enerģijas ierobežojums\n- **Ex nA (bez dzirksteles)**: Piemērots 2. zonas/2. nodaļas lietojumiem\n\n#### 3. Temperatūras klases verifikācija\n\nVārsta maksimālajai virsmas temperatūrai jābūt zemākai par bīstamās vielas aizdegšanās temperatūru:\n\n| Temperatūras klase | Maksimālā virsmas temperatūra | Vielu piemēri |\n| T1 | 450°C | Acetons, amonjaks |\n| T2 | 300°C | Etanols, benzīns |\n| T3 | 200°C | Dīzeļdegviela |\n| T4 | 135°C | Acetaldehīds |\n| T5 | 100°C | Oglekļa disulfīds |\n| T6 | 85°C | Dažas speciālās ķimikālijas |\n\n### Reāla lietojuma piemērs\n\nSārai, projektu inženierei naftas pārstrādes rūpnīcā Teksasā, vajadzēja nomainīt novecojušos solenoīdu vārstus 1. zonas zonā, kurā ir ūdeņraža gāze (IIC grupa, T1). Viņas sākotnējais oriģinālais oriģināliekārtu ražotājs piedāvāja vārstus, kas sertificēti tikai IIB grupai - nepietiekami ūdeņraža lietojumiem. Mēs viņai piegādājām pareizi novērtētus Ex d IIC T4 sertificētus vārstu kolektorus, kas atbilda visām NEC 505 prasībām, novēršot potenciāli bīstamu specifikācijas kļūdu. ✅\n\n## Kādām tehniskajām specifikācijām jāatbilst ATEX/HazLoc vārstiem?\n\nSprādziendrošajiem vārstiem ir jāatbilst ne tikai pamata sertifikācijas marķējumam, bet arī stingrām tehniskajām prasībām, kas ietekmē gan drošību, gan ilgtermiņa uzticamību skarbos vides apstākļos.\n\n**ATEX/HazLoc vārstiem nepieciešama specializēta konstrukcija, tostarp sprādziendrošs korpuss, atbilstošs IP novērtējums (parasti IP65 vai augstāks), sertificēti kabeļu vadi, ekvipotenciālā savienojuma noteikumi un materiāli, kas izturīgi pret korozīvu atmosfēru, vienlaikus saglabājot virsmas temperatūras ierobežojumus visos darba apstākļos.** Dokumentācijā jāiekļauj uzstādīšanas instrukcijas, tehniskās apkopes procedūras un atbilstības sertifikāts.\n\n### Kritiskās tehniskās prasības\n\n#### Elektriskie komponenti\n\n- Elektromagnētiskajām spolēm jābūt sertificētām konkrētai zonai/daļai.\n- Spriegumam un frekvencei jāatbilst sertifikācijas parametriem\n- Ievadiem cauruļvados ir nepieciešami sertificēti kabeļu ieliktņi.\n- Obligātie zemējuma/savienojuma noteikumi\n\n#### Mehāniskā būvniecība\n\n- Apvalka materiāli: Parasti alumīnijs vai nerūsējošais tērauds\n- Aizsardzība pret iekļūšanu: Minimālais IP65 āra/mazgāšanas telpām\n- Izturība pret koroziju: Apsveriet jūras klases vai īpašus pārklājumus.\n- Izturība pret vibrācijām: Saskaņā ar IEC 60068-2-6 standartiem\n\n#### Veiktspējas salīdzinājums: Bepto vs. OEM\n\n| Funkcija | OEM sertificēti vārsti | Bepto sertificēti vārsti |\n| ATEX/HazLoc sertifikācija | ✅ Jā | ✅ Jā (ekvivalents) |\n| Izpildes laiks | 6-10 nedēļas | 1-2 nedēļas |\n| Cenu punkts | Pamatlīnija | 30-40% apakšējā |\n| Tehniskais atbalsts | Ierobežots | Tieša piekļuve inženierim |\n| Pielāgošanas opcijas | Ierobežots | Elastīgas konfigurācijas |\n| Rezerves daļu pieejamība | Bieži kavējas | Stratēģisko krājumu saglabāšana |\n\n### Dokumentācijas prasības\n\nPasūtot pie mums sertificētus vārstus, mēs nodrošinām:\n\n- Atbilstības sertifikāts (CoC)\n- ES atbilstības deklarācija (ATEX)\n- Uzstādīšanas un apkopes rokasgrāmatas angļu valodā\n- Rezerves daļu saraksti ar sertifikācijas informāciju\n- Izsekojamības dokumentācija kvalitātes auditiem\n\nMūsu dokumentācijas pakete ir palīdzējusi klientiem izturēt regulatīvo auditu vairāk nekā 30 valstīs, sākot no farmācijas rūpnīcām Šveicē līdz naftas ķīmijas rūpnīcām Saūda Arābijā.\n\n## Kā Bepto var palīdzēt jums rentabli atrast atbilstošus vārstus?\n\nLai orientētos sarežģītajā sprādziendrošās pneimatikas pasaulē, nav jāizsmeļ jūsu budžets vai jāpagarina projekta termiņi - ja sadarbojaties ar pareizo partneri.\n\n**Bepto specializējas ATEX un HazLoc sertificētu pneimatisko vārstu, cilindru bez stieņiem un pilnu pneimatisko sistēmu nodrošināšanā kā rentablu alternatīvu oriģināliekārtu ražotāju komponentiem ar līdzvērtīgiem sertifikātiem, ātrāku piegādi un pieredzējušu inženieru, kas pārzina gan Eiropas, gan Ziemeļamerikas standartus, tehnisko atbalstu.** Mēs uzturam stratēģisku sertificētu komponentu krājumu, lai samazinātu dīkstāves risku.\n\n### Mūsu sertifikācijas portfelis\n\nMēs aktīvi sertificējamies dažādos standartos:\n\n- **ATEX**: 2G/2D kategorija (zona 1/21) un 3G/3D (zona 2/22)\n- **IECEx**: Starptautiska sertifikācija globāliem projektiem\n- **UL/CSA**: Ziemeļamerikas HazLoc atbilstība\n- **KOSHA**: Korejas sertifikācija Āzijas tirgiem\n\n### Bepto priekšrocības lietojumiem bīstamās zonās\n\n#### Ātrāka piegāde\n\nLai gan oriģināliekārtu ražotāju piegādātājiem sertificētas sastāvdaļas bieži vien ir nepieciešamas 8-12 nedēļas, mūsu stratēģiskie krājumi ļauj mums piegādāt lielāko daļu standarta konfigurāciju 5-10 darba dienu laikā. Pielāgotas konfigurācijas mēs parasti piegādājam 3-4 nedēļu laikā - joprojām 50% ātrāk nekā tradicionālie piegādātāji.\n\n#### Izmaksu optimizācija bez kompromisiem\n\nMūsu uzņēmējdarbības modelis ir vērsts uz sertificētu rezerves komponentu, kas atbilst vai pārsniedz oriģināliekārtu ražotāju specifikācijas, nodrošināšanu par ievērojami zemākām cenām. Nesen kāds pārtikas pārstrādes uzņēmums Ontārio provincē nomainīja visu pneimatiskās vadības sistēmu ar Bepto sertificētiem vārstiem, ietaupot $47 000 projekta laikā, vienlaikus nodrošinot pilnīgu atbilstību Kanādas HazLoc prasībām.\n\n#### Tehniskās konsultācijas\n\nSazinoties ar mums, jūs runāsiet tieši ar inženieriem, kuri saprot:\n\n- Teritoriju klasifikācijas metodoloģijas\n- Savstarpējās sertifikācijas ekvivalenti (ATEX ↔ HazLoc)\n- Materiālu izvēle korozīvām vidēm\n- Integrācija ar esošajām vadības sistēmām\n- Tehniskās apkopes optimizācijas stratēģijas\n\n### Darba sākšana\n\nJa plānojat projektu bīstamā zonā vai ja nepieciešams nomainīt esošos sertificētos komponentus, sazinieties ar mūsu komandu. Mēs izskatīsim jūsu specifikācijas, apstiprināsim sertifikācijas prasības un sniegsim detalizētu piedāvājumu ar sertifikācijas dokumentāciju - parasti 24 stundu laikā.\n\n## Secinājums\n\nLai noteiktu vārstus ATEX un HazLoc videi, ir jāpievērš īpaša uzmanība sertifikācijas standartiem, tehniskajām specifikācijām un atbilstošai dokumentācijai, taču ar pareizo piegādātāju partneri jūs varat panākt pilnīgu atbilstību, vienlaikus ievērojami samazinot izmaksas un sagatavošanas laiku.\n\n## Bieži uzdotie jautājumi par ATEX HazLoc vārstu specifikāciju\n\n### **J: Vai Ziemeļamerikas HazLoc lietojumos var izmantot ATEX sertificētus vārstus?**\n\nATEX un HazLoc sertifikāti nav tieši savstarpēji aizvietojami, lai gan iekārtām var būt divi sertifikāti. Jums jāpārliecinās, vai jūsu vārstam ir konkrētais sertifikāts, ko pieprasa jūsu vietējā jurisdikcija - ATEX - ES, UL/CSA - Ziemeļamerikā. Mēs varam piegādāt vārstus ar dubultu sertifikāciju, lai vienkāršotu globālos projektus.\n\n### **J: Kāda ir atšķirība starp 1. un 2. zonas vārstu prasībām?**\n\n1. zonas (vai 1. nodaļas) zonās pastāvīgi vai bieži ir sprādzienbīstama vide, tāpēc ir nepieciešami augstāki aizsardzības līmeņi, piemēram, Ex d vai Ex ia. 2. zonas (2. nodaļas) zonās bīstamība pastāv tikai ārkārtējos apstākļos, un tajās pieļaujamas vienkāršākas aizsardzības metodes, piemēram, Ex nA. 1. zonas iekārtas var izmantot 2. zonā, bet ne otrādi.\n\n### **J: Cik bieži jāpārsertificē vai jāpārbauda ATEX/HazLoc vārsti?**\n\nPašiem vārstiem nav nepieciešama atkārtota sertifikācija, taču jūsu objektā ir jāveic regulāras pārbaudes saskaņā ar vietējiem noteikumiem - parasti reizi gadā 1. zonas 1. nodaļas zonās. Veiciet uzstādīšanas uzskaiti, vizuāli pārbaudiet, vai nav bojājumu, un pārliecinieties par pareizu zemējumu. Katram pasūtījumam mēs pievienojam tehniskās apkopes vadlīnijas, lai palīdzētu jums nodrošināt atbilstību prasībām.\n\n### **J: Vai pneimatiskie vārsti sprādzienbīstamā vidē ir drošāki par elektriskajiem vārstiem?**\n\nPneimatiskie vārsti parasti rada mazāku aizdegšanās risku, jo to iedarbināšanas punktā nav elektrisko komponentu, lai gan solenoīda pilotvārstiem joprojām nepieciešama atbilstoša sertifikācija. Pneimatiskās sistēmas var būt izdevīgas īpaši bīstamās zonās. Mēs varam jums palīdzēt novērtēt labāko pieeju jūsu konkrētajam lietojumam un riska profilam.\n\n### **J: Kas notiek, ja es bīstamā zonā uzstādu nesertificētus vārstus?**\n\nNesertificēta aprīkojuma uzstādīšana klasificētās zonās pārkāpj drošības noteikumus, anulē apdrošināšanas segumu, jūsu uzņēmumam draud lielas soda naudas un, kas ir vissvarīgākais, rada patiesu sprādziena risku, kas apdraud personālu. Pārvaldes inspektori pieprasīs nekavējoties pārtraukt darbu, līdz tiks uzstādītas atbilstošas iekārtas. Pirms uzstādīšanas vienmēr pārbaudiet sertifikāciju - mūsu komanda var palīdzēt ātri apstiprināt atbilstību.\n\n1. Izlasiet Eiropas Komisijas oficiālās vadlīnijas par ATEX. [↩](#fnref-1_ref)\n2. Skatiet OSHA un NEC bīstamo vietu (HazLoc) definīcijas. [↩](#fnref-2_ref)\n3. Piekļūstiet ES Direktīvas 2014/34/ES pilnam juridiskajam tekstam. [↩](#fnref-3_ref)\n4. Uzziniet vairāk par IEC 60079-0 standartu attiecībā uz iekārtu aizsardzības līmeņiem (EPL). [↩](#fnref-4_ref)\n5. Izpratne par iekšējās drošības (IS) principiem kā aizsardzības pret aizdegšanos metodi. [↩](#fnref-5_ref)","links":{"canonical":"https://rodlesspneumatic.com/lv/blog/how-to-specify-valves-for-atex-hazloc-environments/","agent_json":"https://rodlesspneumatic.com/lv/blog/how-to-specify-valves-for-atex-hazloc-environments/agent.json","agent_markdown":"https://rodlesspneumatic.com/lv/blog/how-to-specify-valves-for-atex-hazloc-environments/agent.md"}},"ai_usage":{"preferred_source_url":"https://rodlesspneumatic.com/lv/blog/how-to-specify-valves-for-atex-hazloc-environments/","preferred_citation_title":"Kā noteikt vārstus ATEX / HazLoc videi","support_status_note":"Šajā paketē ir pieejams publicētais WordPress raksts un iegūtās avota saites. Tas neatkarīgi nepārbauda katru apgalvojumu."}}