Inputs
- Measured package input power
- Free air delivery
- FAD unit
- Measured load fraction
Compressor efficiency
Calculate compressor specific power, kW per 100 cfm, cfm per kW, and hourly electrical energy from measured input and FAD. Enter the application values to calculate four decision-ready outputs and review the governing assumptions before selecting equipment.
Compressor efficiency
Calculate compressor specific power, kW per 100 cfm, cfm per kW, and hourly electrical energy from measured input and FAD. Enter the application values to calculate four decision-ready outputs and review the governing assumptions before selecting equipment.
Engineering visual
The compressor converts electrical input into compressed-air output and heat. Capacity, pressure, specific power, and recoverable heat are shown by energy path.
Calculation reference
Use the displayed relationship to understand how the entered conditions affect the result. Treat the output as a preliminary selection, then verify actual operating conditions, catalog limits, and safety margin.
Engineering guide
Calculate compressor specific power calculator for a pneumatic application and compare the result with supplier data.
Enter Measured package input power, Free air delivery, FAD unit and replace every default with application data.
Run the calculation while keeping pressure, temperature, geometry, and reference states consistent.
Interpret Specific power, kW per 100 cfm, Flow per input kW against the supplier datasheet, machine risk, and an appropriate design margin.
Reference pressure, temperature, humidity, and flow basis must stay consistent; standard and actual volume are not interchangeable.
Replace default correction factors with measured plant data and supplier ratings before equipment purchase.
Start with measured or supplier-confirmed values for Measured package input power, Free air delivery, FAD unit, Measured load fraction. The calculator updates all outputs together, making it easier to see which assumption controls the preliminary selection.
Specific power, kW per 100 cfm, Flow per input kW, Energy per operating hour answer different parts of the same engineering question. Use the primary result for selection, the secondary values to audit units and margins, and the visible formula to reproduce the calculation in an RFQ worksheet.
Reference pressure, temperature, humidity, and flow basis must stay consistent; standard and actual volume are not interchangeable. Replace default correction factors with measured plant data and supplier ratings before equipment purchase. Final approval requires the current manufacturer datasheet and validation under installed conditions.
FAQ