Inputs
- Equivalent orifice diameter
- Upstream gauge pressure
- Downstream gauge pressure
- Air temperature
- Discharge coefficient
Cushion restriction
Estimate compressible air flow through a cushion needle or equivalent orifice using diameter, pressure ratio, temperature, and discharge coefficient. Enter the application values to calculate four decision-ready outputs and review the governing assumptions before selecting equipment.
Cushion restriction
Estimate compressible air flow through a cushion needle or equivalent orifice using diameter, pressure ratio, temperature, and discharge coefficient. Enter the application values to calculate four decision-ready outputs and review the governing assumptions before selecting equipment.
Engineering visual
Upstream pressure drives flow through the valve restriction to downstream pressure. The restriction and pressure drop are shown at the component where they occur.
Calculation reference
Use the displayed relationship to understand how the entered conditions affect the result. Treat the output as a preliminary selection, then verify actual operating conditions, catalog limits, and safety margin.
Engineering guide
Calculate cushion orifice flow calculator for a pneumatic application and compare the result with supplier data.
Enter Equivalent orifice diameter, Upstream gauge pressure, Downstream gauge pressure and replace every default with application data.
Run the calculation while keeping pressure, temperature, geometry, and reference states consistent.
Interpret Estimated standard flow, Estimated flow in SCFM, Equivalent orifice area against the supplier datasheet, machine risk, and an appropriate design margin.
Air is treated as an ideal gas and the entered coefficient or geometry must match the supplier's stated reference conditions.
Confirm the entire flow path, including tubing, fittings, manifolds, silencers, and simultaneous valve demand.
Start with measured or supplier-confirmed values for Equivalent orifice diameter, Upstream gauge pressure, Downstream gauge pressure, Air temperature. The calculator updates all outputs together, making it easier to see which assumption controls the preliminary selection.
Estimated standard flow, Estimated flow in SCFM, Equivalent orifice area, Absolute downstream/upstream ratio answer different parts of the same engineering question. Use the primary result for selection, the secondary values to audit units and margins, and the visible formula to reproduce the calculation in an RFQ worksheet.
Air is treated as an ideal gas and the entered coefficient or geometry must match the supplier's stated reference conditions. Confirm the entire flow path, including tubing, fittings, manifolds, silencers, and simultaneous valve demand. Final approval requires the current manufacturer datasheet and validation under installed conditions.