AI Search

Search this site

Sonic conductance

ISO 6358 Sonic Conductance Air Flow Calculator

Estimate standard air flow from ISO 6358 sonic conductance C, critical pressure ratio b, and upstream and downstream pressures.

Sonic conductance

Run the calculation

Estimate standard air flow from ISO 6358 sonic conductance C, critical pressure ratio b, and upstream and downstream pressures.

Engineering inputsISO 6358 Flow Calculator

Enter the known application values. Outputs update instantly as units or assumptions change.

Use these values for preliminary sizing before final datasheet review.

Engineering visual

ISO 6358 Flow Calculator calculation path

Upstream pressure drives flow through the valve restriction to downstream pressure. The restriction and pressure drop are shown at the component where they occur.

ISO 6358 Flow Calculator calculation pathUpstream pressure drives flow through the valve restriction to downstream pressure. The restriction and pressure drop are shown at the component where they occur.UPSTREAM p₁DOWNSTREAM p₂VALVE / ORIFICEFLOW QΔp = p₁ − p₂
  1. 01Sonic conductance C
  2. 02Calculate and compare
  3. 03Standard flow
Standard flow
Standard flow in SCFM
Absolute pressure ratio
Subcritical flow factor

Calculation reference

Calculation method

Results are preliminary estimates. Actual operating conditions, component ratings, and the required safety margin determine whether a component is suitable.

Inputs

  • Sonic conductance C
  • Critical pressure ratio b
  • Upstream gauge pressure
  • Downstream gauge pressure

Outputs

  • Standard flow
  • Standard flow in SCFM
  • Absolute pressure ratio
  • Subcritical flow factor

Engineering guide

Use the result with the right context.

Estimate standard air flow from ISO 6358 sonic conductance C, critical pressure ratio b, and upstream and downstream pressures.

Calculation workflow
  1. Enter Sonic conductance C, Critical pressure ratio b, Upstream gauge pressure and replace every default with application data.

  2. Run the calculation while keeping pressure, temperature, geometry, and reference states consistent.

  3. Interpret Standard flow, Standard flow in SCFM, Absolute pressure ratio against the supplier datasheet, machine risk, and an appropriate design margin.

Assumptions and limits
  • Air is treated as an ideal gas and the entered coefficient or geometry must match the supplier's stated reference conditions.

  • Confirm the entire flow path, including tubing, fittings, manifolds, silencers, and simultaneous valve demand.

FAQ

Questions about this calculation

01Tool noteWhat does the ISO 6358 Flow Calculator calculate?

Estimate standard air flow from ISO 6358 sonic conductance C, critical pressure ratio b, and upstream and downstream pressures.

02Tool noteCan I use the result as a final component selection?

No. These are preliminary estimates. Final selection also depends on supplier ratings, installation losses, transient conditions, applicable standards, machine risk, and validation testing.

03Tool noteWhy can a supplier calculation differ?

Supplier tools may use proprietary test curves, correction factors, rounding, leakage allowances, or reference conditions. Match those conditions and replace the defaults before comparing results.

04Tool noteWhat should I verify after using the ISO 6358 Flow Calculator?

Check the entered units and reference conditions, then compare the calculated outputs with manufacturer ratings, application safety margins, transient loads, installation losses, and measured machine performance.